- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
In Vivo Multitracer Analysis Technique: Screening of Radioactive Probes for Noninvasive Measurement of Physiological Functions in Experimental Animals
-
- Matsumoto Ken-ichiro
- Department of Physical Chemistry, Showa Pharmaceutical University
-
- Hirunuma Rieko
- Radioisotope Technology Division, Cyclotron Center, RIKEN (The Institute of Physical and Chemical Research)
-
- Enomoto Shuichi
- Radioisotope Technology Division, Cyclotron Center, RIKEN (The Institute of Physical and Chemical Research)
-
- Endo Kazutoyo
- Department of Physical Chemistry, Showa Pharmaceutical University
Search this article
Description
A novel screening experiment, to find radioactive probes for non-invasive measurements of physiological functions in experimental animals, was tested using the in vivo multitracer analysis technique. The details of the efficiency of the detector settings used in the in vivo multitracer analysis technique were examined by both computer simulations and practical measurements. Multiple radioactive isotopes, i.e. multitracer, were prepared by irradiating a silver foil target with a heavy ion beam at the RIKEN ring cyclotron. After chemical separation of the silver target, the multitracer was finally dissolved in isotonic citrate buffer. The multitracer solution was intravenously injected into rats. Using a γ-ray detector equipped with a well-defined slit, the collimated γ-rays from the upper abdomen of living rats were measured. After correction of detection efficiencies, it was possible to compare the distribution of radioactive elements between two groups of rats different in body weight. The in vivo measurement showed that the tissue substantial volume of the selenium-deficient (SeD) rat liver increased compared to normal rats. The possibility of a functional estimation of tissue/blood volume for living rats was proposed based on the characteristic in vivo distribution of 74As, 83Rb and 103Ru.
Journal
-
- Biological and Pharmaceutical Bulletin
-
Biological and Pharmaceutical Bulletin 28 (11), 2029-2034, 2005
The Pharmaceutical Society of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679603363456
-
- NII Article ID
- 10016783193
-
- NII Book ID
- AA10885497
-
- ISSN
- 13475215
- 09186158
-
- NDL BIB ID
- 7675357
-
- PubMed
- 16272684
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed