- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Effect of Geometrical Structure on the Biodegradation of a Three-Dimensionally Perforated Porous Apatite/Collagen Composite Bone Cell Scaffold
-
- Hamada Hideyuki
- Faculty of Pharmaceutical Sciences, Tokyo University of Science
-
- Ohshima Hiroyuki
- Faculty of Pharmaceutical Sciences, Tokyo University of Science
-
- Ito Atsuo
- National Institute of Advanced Industrial Science and Technology
-
- Higuchi William I.
- Department of Pharmaceutics and Pharmaceutical Chemistry, University of Utah
-
- Otsuka Makoto
- Research Institute of Pharmaceutical Sciences, Faculty of Pharmacy, Musashino University
Search this article
Description
A Biodegradable artificial bone with inter-connective pores was prepared using a self-setting apatite/collagen composite cement as a cell scaffold for bone regenerative medicine, and investigated as to biocompatibility by X-ray computed tomography (CT) after its implantation into rats. Blocks (APN, APC and ACC) of apatite cement, apatite cement with continuous holes, and apatite/collagen composite cement with continuous holes were prepared. The APC and ACC blocks had 16 (8×2) interconnecting holes 500 μm in diameter. After the APN, APC, and ACC blocks were implanted in the back of the rats, X-ray CT images were measured every week. Before and after implantation, powder X-ray diffraction profiles of APN, APC and ACC showed diffraction patterns of hydroxyapatite with low crystallinity. Changes in the volume, inorganic content and density of the blocks in the rats were evaluated based on X-ray CT images. The volume and inorganic content of ACC decreased continuously at a constant rate. In contrast, the volume and inorganic content of APN and APC didn't show major changes. After implantation, the absorption of X-rays by ACC decreased with time. This suggested that the block was bioabsorbed significantly with time. In contrast, the absorption of APC and APN did not decrease, indicating that the blocks were not bioabsorbed.
Journal
-
- Biological and Pharmaceutical Bulletin
-
Biological and Pharmaceutical Bulletin 33 (7), 1228-1232, 2010
The Pharmaceutical Society of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679604979840
-
- NII Article ID
- 130000300292
-
- NII Book ID
- AA10885497
-
- ISSN
- 13475215
- 09186158
-
- NDL BIB ID
- 10738328
-
- PubMed
- 20606318
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed