深呼吸負荷時における心電図R‐R間隔の変動についての検討

書誌事項

タイトル別名
  • Measurement of R-R Interval Variations under Deep Breathing Load in Healthy Persons.
  • シンコキュウ フカジ ニ オケル シンデンズ R R カンカク ノ ヘンドウ ニ ツイテ ノ ケントウ

この論文をさがす

説明

In order to examine the effect of breathing depth and respiratory minute rate on R-R interval variations during deep breath, standard deviation (SD), coefficient of variation (CV) of R-R interval and a difference between the maximum heart rate and the minimum heart rate (DHR) were measured. Compared with the static condition, CV was increased by 27.3% with the half breathing depth, and by 101.8% with the maximum breathing depth. DHR was not changed with the half breathing depth, and that was increased by 25.4% with the maximum breathing depth. There was a significant (p<0.001) difference in CV and SD of healthy subjects between 6 times/min of respiratory minute rate and the static condition, but not between 12 times/min of respiratory minute rate and the static condition. SD and CV of patients with SMON at 12 times/min of respiratory minute rate were significantly (p<0.05) lower than those at static condition.

収録刊行物

被引用文献 (2)*注記

もっと見る

参考文献 (16)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ