- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Automatic Translation feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Study on Use of Fuel-Cell Auxiliary Power Units in Refrigerator Cars Employed for Delivery to Convenience Store
-
- Katayama Noboru
- Tokyo University of Science
-
- Kamiyama Hideyuki
- Tokyo University of Science
-
- Kogoshi Sumio
- Tokyo University of Science
-
- Kudo Yusuke
- Nihon University
-
- Fukada Takafumi
- Isuzu Advanced Engineering Center, Ltd.
-
- Ogawa Makoto
- Isuzu Advanced Engineering Center, Ltd.
Bibliographic Information
- Other Title
-
- 燃料電池補助電源のコンビニエンスストアー配送用冷凍車への適用の検討
- ネンリョウ デンチ ホジョ デンゲン ノ コンビニエンスストアー ハイソウヨウ レイトウシャ エ ノ テキヨウ ノ ケントウ
Search this article
Description
The use of fuel-cell auxiliary power units (FC-APU) in refrigerator cars employed delivery to for convenience store delivery has been studied. The delivery pattern is assumed to be a typical pattern that includes driving between convenience stores or between a delivery center and a convenience store, unloading, driver's lunch break. The M15 driving mode, which simulates the driving condition in urban areas, is used as the driving mode in the delivery pattern. The FC-APU system includes a proton-exchange membrane fuel cell (PEFC) module, an inverter, and DC/DC converter. Bench tests of the FC-APU are performed to determine the hydrogen fuel consumption rate and the energy efficiency; these values depend on the output power of the PEFC module. The calculated relationship between the output power and fuel consumption rate of a current used system, which consists of an alternator and a secondary battery, are used to estimate the energy efficiency of the current used system. On the basis of the measurement data in this study and the results for the model proposed by Brodric et al. [C. J. Brodrick et al., Trans. Res. D, vol 7, pp. 303 (2002)], the payback period is calculated. The results indicate that the payback period would be 2.1 years when the FC-APU operates at a load of 70%.
Journal
-
- IEEJ Transactions on Industry Applications
-
IEEJ Transactions on Industry Applications 131 (1), 39-44, 2011
The Institute of Electrical Engineers of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679634735104
-
- NII Article ID
- 10027637192
-
- NII Book ID
- AN10012320
-
- ISSN
- 13488163
- 09136339
-
- NDL BIB ID
- 10934575
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed