Analysis and Compensation of Voltage Error Caused by the Dead Time in Three-Phase Voltage-Source Converters

  • Mannen Tomoyuki
    Department of Electrical and Electronic Engineering, Tokyo Institute of Technology
  • Fujita Hideaki
    Department of Electrical and Electronic Engineering, Tokyo Institute of Technology

Bibliographic Information

Other Title
  • 電圧形PWM変換器のデッドタイムに起因する電圧誤差の解析と補償
  • デンアツケイ PWM ヘンカンキ ノ デッドタイム ニ キイン スル デンアツ ゴサ ノ カイセキ ト ホショウ

Search this article

Description

This paper discusses the voltage error caused by the dead time in voltage-source PWM converters. The theoretical analysis in this paper derives the nonlinear voltage error paying attention to the parasitic output capacitance in each switching device. The analytical result reveals that the turn-off current or the switching current ripple strongly affects the voltage error. In addition, it is also clarified that the conventional compensation methods based on linear and three-level approximations are suitable for small and large current ripple conditions, respectively. A simple calculation method of current ripples is also developed to estimate the turn-off currents in three-phase PWM converters. A compensation method based on the analysis is developed and compared with three different conventional methods in experiments using a 200-V, 5-kW three-phase grid-connection converter. The analysis-based method exhibits a good compensation performance, having a lower voltage THD than the conventional methods over a wide operating range.

Journal

Citations (4)*help

See more

References(3)*help

See more

Details 詳細情報について

Report a problem