Rapid polarographic determination of manganese in ferromanganese and manganese slag
-
- NAKAGAWA Genkichi
- Nagoya Institute of Technology
Bibliographic Information
- Other Title
-
- ポーラログラフによるフェロマンガンおよびマンガンスラッグ中のマンガンの迅速定量法について
- ポーラログラフ ニ ヨル フェロ マンガン オヨビ マンガン スラッグ チュウ ノ マンガン ノ ジンソク テイリョウホウ ニ ツイテ
Search this article
Abstract
A rapid method of the polarographic determination of Mn in ferromanganese and manganese slag has been examined, and the analysis has been tried on practical samples. pH values, maximum suppressive agents, interfering ions, etc. have Leen investigated in the quantitative determination of Mn (III) by the use of the pyrophosphate supporting electrolyte proposed by Kolthoff, et al.; and it was found that Ni, Co, Cu, Zn, Pb, etc. in 0.3 M pyrophosphate showed no disturbing effect, and gave a definite polarographic wave. A good proportional relationship was shown within the pH range of 2.53.4 and about 50 mg Mn/100 ml. The interference of Fe became negligible by increasing the pH value, but Cl, Cr, V, etc. showed a disturbing effect on the Mn wave.
Journal
-
- BUNSEKI KAGAKU
-
BUNSEKI KAGAKU 7 (1), 25-28, 1958
The Japan Society for Analytical Chemistry
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679638096128
-
- NII Article ID
- 130000954839
-
- NII Book ID
- AN00222633
-
- NDL BIB ID
- 10104783
-
- ISSN
- 05251931
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed