CO<Sub>2</Sub> を作動媒体とした冷房サイクルの性能予測法

  • 小山 繁
    九州大学大学院総合理工学研究院
  • XUE Jun
    九州大学大学院総合理工学府環境エネルギー工学専攻
  • 桑原 憲
    九州大学大学院総合理工学研究院

書誌事項

タイトル別名
  • Performance Prediction Method of CO<Sub>2</Sub> Cycle for Air Cooling
  • CO2を作動媒体とした冷房サイクルの性能予測法
  • CO2 オ サドウ バイタイ ト シタ レイボウ サイクル ノ セイノウ ヨソクホウ

この論文をさがす

抄録

From the perspective of global environmental protection and energy-saving, the research and development on high-efficiency heat pump and refrigeration systems using environment-friendly refrigerants have become one of the most important issues in the air-conditioning and refrigeration sector. In the present work, a steady-state model of the CO2 transcritical cycle for air cooling, which consists of a rotary compressor, a fin-tube gas cooler,a fin-tube evaporator and an expansion valve, has been developed. The detailed model of fin-tube heat exchanger has been constructed by means of the finite volume method, in which the local heat transfer and flow characteristics are evaluated. It should be noted that the effects of the dew condensation generated on the cooling surface are considered in the evaporator model. As a calculation example, the effects of the indoor air wet-bulb temperature on the cycle performance have been examined with this developed simulator.