書誌事項
- タイトル別名
-
- Measurement of a Liquid film Inside a Steam-water Two-fluid Nozzle Using an Optical Fiber Probe
- ヒカリ ファイバー プローブ ニ ヨル ミズ スイジョウキ ニリュウタイ ノズル ナイ ノ エキマク ケイソク
この論文をさがす
抄録
Optical fiber probing is one of the efficient and reliable measurement methods for gas-liquid two-phase flows. We employed the proving for the measurement of a liquid film inside a two-fluid nozzle. First, we verified the availability of the optical fiber probe in the measurement of the liquid film via calibration experiments and numerical analysis. It was validated that the average film thickness and the amplitude of the thickness fluctuation are measured correctly. Second, we performed two kinds of measurements using a steam-water two-fluid transparent nozzle; the one is the newly developed optical fiber probing stated above and the other is LIF visualization with a high-speed video camera. The following results were obtained from both measurements. The average thickness of the liquid film measured by the optical fiber probe was 61 μm and the amplitude of the liquid film fluctuation was 28 μm. These results were agreed with those obtained by the LIF visualization.
収録刊行物
-
- 日本冷凍空調学会論文集
-
日本冷凍空調学会論文集 27 (2), 149-160, 2010
公益社団法人 日本冷凍空調学会
- Tweet
キーワード
詳細情報 詳細情報について
-
- CRID
- 1390282679641752064
-
- NII論文ID
- 10026793827
-
- NII書誌ID
- AA11125910
-
- BIBCODE
- 2011TRACE..27..149M
-
- ISSN
- 2185789X
- 13444905
-
- NDL書誌ID
- 10767560
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可