Precise Dilatometric Measurements of Silica Glasses.

Bibliographic Information

Other Title
  • 石英ガラスの熱膨張率の精密測定

Search this article

Description

The linear thermal expansion coefficients (LTEC) of silica glasses produced by the Nippon Glass lnc. Ltd. have been measured in the temperature range 0 ∼50°C using an interferometric dilatometer. The measurement system consists of a double-path optical heterodyne interferometer and a compact vaccum thermal bath controlled by a thermoelectric transducer. Before measuring the silica glass specimens, the reliability checks of the dilatometer were perfomed on silicon and fused silica SRM 739. The resultant estimated maximum uncertainty of the measured LTECs is about±2×10-8K-1. The measurement results indicated that, around room temperature (0∼50°C), only a factor of CI-rich content in silica glass affects the thermal expansion characteristics of the silica glass reducing slightly its absolute values, nevertheless the differences in the LTECs for all of the investigated specimens are sufficiently small within 4×10-8K-1

Journal

  • Netsu Bussei

    Netsu Bussei 13 (1), 17-22, 1999

    JAPAN SOCIETY OF THERMOPHYSICAL PROPERTIES

Citations (1)*help

See more

References(3)*help

See more

Details 詳細情報について

  • CRID
    1390282679643355904
  • NII Article ID
    130004495591
  • DOI
    10.2963/jjtp.13.17
  • COI
    1:CAS:528:DyaK1MXhsFKmsbk%3D
  • ISSN
    1881414X
    0913946X
  • Text Lang
    en
  • Data Source
    • JaLC
    • Crossref
    • CiNii Articles
  • Abstract License Flag
    Disallowed

Report a problem