A Study of Pre-Cooling System by using Adsorption Cool Storage for Automobiles
-
- INOUE Satoshi
- Corporate R&D Dept.1, DENSO CORPORATION
-
- INOUE Seiji
- Corporate R&D Dept.1, DENSO CORPORATION
-
- KOBAYASHI Noriyuki
- EcoTopia Science Institute, Nagoya University
Bibliographic Information
- Other Title
-
- 吸着式蓄冷器を用いた自動車の乗車前空調の研究
- キュウチャクシキチクレイキ オ モチイタ ジドウシャ ノ ジョウシャ ゼン クウチョウ ノ ケンキュウ
Search this article
Abstract
In this paper, we studied a pre-cooling system by using adsorption cool storage for automobiles on the purpose of getting a cool breeze immediately after getting on. The adsorbent should be appropriate depends on the operation condition of adsorption cool storage. We found that FAPO34 is appropriate because the adsorbed amount increases at the relative humidity 0.05. We verified the effect by simulations and experiments. As results, it was proven to be able to lower the temperature of the blow air from 60°C to 35°C when the cool storage which uses absorbent 1.0kg was operated for 60 seconds before getting on.
Journal
-
- Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers
-
Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers 26 (2), 141-148, 2009