Measurement of Gas Solubility for Pure Liquids Using Static Method
-
- SATO Takashi
- Kansai University
-
- HAMADA Yuzo
- Kansai University
-
- YAMAMOTO Hideki
- Kansai University
Bibliographic Information
- Other Title
-
- 静止法による液体に対するガス溶解度の測定
- セイシホウ ニ ヨル エキタイ ニ タイスル ガス ヨウカイド ノ ソクテイ
Search this article
Abstract
The gas solubility in pure solvents was an important data in design of chemical plants such as absorption tower, oil industry and others. At our laboratory, development and improvement of measurement apparatus for gas solubility to liquid have been performed. Solubility of oxygen was determined in 15 pure solvents. Gas solubility measurements were carried out at 298.2K and 101.3kPa. The solubility has been expressed as Ostwald coefficient of gas dissolved. In the results of gas solubility measurements, reproducibility of Ostwald coefficient was ±0.54% on the average for 15 pure solvents. Average deviation between observed and literature gas solubility was 1.36%. Standard uncertainty of Ostwald coefficient by measurement was 1.21×10-3 on the average for 15 pure solvents.
Journal
-
- Netsu Bussei
-
Netsu Bussei 25 (4), 194-199, 2014
JAPAN SOCIETY OF THERMOPHYSICAL PROPERTIES
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679644353024
-
- NII Article ID
- 10029650724
-
- NII Book ID
- AN10064743
-
- ISSN
- 1881414X
- 0913946X
-
- NDL BIB ID
- 023348066
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed