Heat Storage Characteristics of Latent-Heat Microcapsule Slurry Using Hot Air Bubbles by Direct-Contact Heat Exchange.
-
- INABA Hideo
- Graduate School of Natural Science and Technology, Okayama University
-
- HORIBE Akihiko
- Graduate School of Natural Science and Technology, Okayama University
-
- KIM Myoung-Jun
- Graduate School of Natural Science and Technology, Okayama University
-
- TSUKAMOTO Hirofumi
- Graduate School of Natural Science and Technology, Okayama University
この論文をさがす
抄録
This study deals with the heat storage characteristics of latent-heat microcapsule slurry consisting of a mixture of fine microcapsules packed with latent-heat storage material and water. The heat storage operation for the latent-heat microcapsules was carried out by the direct-contact heat exchange method using hot air bubbles. The latent-heat microcapsule consisted of n-paraffin as a core latent-heat storage material and melamine resin as a coating substance. The relationship between the completion time of latent-heat storage and some parameters was examined experimentally. The nondimensional correlation equations for temperature efficiency, the completion time period of the latent-heat storage process and variation in the enthalpy of air through the microcapsule slurry layer were derived in terms of the ratio of microcapsule slurry layer height to microcapsule diameter, Reynolds number for airflow, Stefan number and modified Stefan number for absolute humidity of flowing air.
収録刊行物
-
- JSME International Journal Series B Fluids and Thermal Engineering
-
JSME International Journal Series B Fluids and Thermal Engineering 44 (3), 328-336, 2001
一般社団法人 日本機械学会