書誌事項
- タイトル別名
-
- Usefulness of a membrane filter in the cell block method and endometrial cytology.
この論文をさがす
説明
We contrived a simple and efficient method of preparing paraffin-embedded cell blocks with the use of a membrane filter (Filter cell block, MFCB). We used MFCB together with routine endometrial cytology and examined its usefulness. The study group consisted of 427 patients who visited the Gynecology Clinic of Otemae Hospital. In 72 (17%) cases which could not be diagnosed because of scanty cells on cytological smears, 24 (6%) cases could be diagnosed with the use of MFCB. In 28 (6.6%) cases in which epithelial neoplasia or related lesions were suspected, 12 (2.8%) cases were examined by endometrial curettage or using hysterectomy materials and a final histological diagnosis was made. These were 9 (2.1%) cases of endometrial hyperplasia, 2 (0.5%) cases of atypical endometrial hyperplasia and 1 (0.2%) case of endometrial cancer. This study found that the use of a membrane filter can simplity and improve the preparation of paraffin-embedded cell blocks and lead to progress in the diagnostic accuracy of screening for endometrial cancer.
収録刊行物
-
- 日本臨床細胞学会雑誌
-
日本臨床細胞学会雑誌 37 (1), 32-35, 1998
公益社団法人 日本臨床細胞学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679669777920
-
- NII論文ID
- 130003926437
- 110001224197
-
- NII書誌ID
- AN00198721
-
- ISSN
- 18827233
- 03871193
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可