Fire Experiment on Diagonally Arranged External Louver for Integrated Facade System

Bibliographic Information

Other Title
  • 統合ファサードにおける斜行ルーバーに関する実大火災実験―斜行ルーバー近傍の開口噴出気流性状―
  • トウゴウ ファサード ニ オケル シャコウ ルーバー ニ カンスル ジツダイ カサイ ジッケン シャコウ ルーバー キンボウ ノ カイコウ フンシュツ キリュウ セイジョウ
  • FIRE EXPERIMENT ON DIAGONALLY ARRANGED EXTERNAL LOUVER FOR INTEGRATED FAÇADE SYSTEM

Search this article

Description

The building facade plays an important role not only for ornament designs, but also for the safety and environmental impacts of the building. To satisfy these demands, the authors have proposed an integrated facade system using diagonally arranged louvers. When considering the safety, not only the structural aspect but also the safety aspect is important. Especially the verification of the behavior of the ejected plume from the building's openings is important as to prevent the fire from spreading. A full scale fire experiment, in which the louvers were attached to the opening, has been carried out. The ejected plume behavior from the opening was verified through temperature and radiated heat measurement around the opening and the louvers and through study of the shape of the plume.

Journal

  • Fire Science and Technology

    Fire Science and Technology 28 (2), 51-68, 2009

    Center for Fire Science and Technology, Research Institute for Science and Technology, Tokyo University of Science

Citations (1)*help

See more

References(11)*help

See more

Details 詳細情報について

Report a problem