- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Evaluation of the Microsemi LC‐662 Hematology Analyzer for Dog and Cat Blood Specimens
-
- NEO Sakurako
- Laboratory of Small Animal Internal Medicine, School of Veterinary Medicine, Azabu University
-
- HISASUE Masaharu
- Laboratory of Small Animal Internal Medicine, School of Veterinary Medicine, Azabu University
-
- TSUCHIYA Ryo
- Laboratory of Small Animal Internal Medicine, School of Veterinary Medicine, Azabu University
Bibliographic Information
- Other Title
-
- 犬及び猫の血液を用いた動物用自動血球計数装置Microsemi LC‐662の評価
- 犬及び猫の血液を用いた動物用自動血球計数装置Microsemi LC-662の評価
- イヌ オヨビ ネコ ノ ケツエキ オ モチイタ ドウブツヨウ ジドウ ケッキュウ ケイスウ ソウチ Microsemi LC-662 ノ ヒョウカ
Search this article
Description
<p>Accurate platelet count measurement with point-of-care testing (POCT) using an automated impedance-based hematology analyzer is difficult, particularly in cats. Microsemi LC‐662 (LC) is a new POCT automated impedance-based hematology analyzer for use in veterinary clinics. In this study, we compared the performance of POCT analyzers LC and Celltac α (Cα) with Sysmex XT‐2000iV (XT) in measuring hematological variables in dogs and cats. To cope with the delayed measurement of complete blood count (CBC), which can occur in clinics, we also determined the storage effects on hematological data collected using LC. Blood samples from healthy dogs and cats (nine dogs and five cats), as well as from dogs and cats that were brought to our hospital (90 dogs and 62 cats), were included in the study. To study the storage effects on hematological data, we used nine healthy dogs and five healthy cats. In dogs, platelet counts measured using LC and Cα were highly correlated with those measured using XT. In cats, platelet counts measured using LC were highly correlated with those measured using XT; however, platelet counts measured using only Cα were moderately correlated with those measured using XT. Both time and temperature effects on CBC data were assessed for stored blood. Prolonged storage and low temperature resulted in significantly decreased platelet counts and increased white blood cell counts in both dogs and cats.</p>
Journal
-
- Journal of the Japan Veterinary Medical Association
-
Journal of the Japan Veterinary Medical Association 70 (12), 795-799, 2017
Japan Veterinary Medical Association
- Tweet
Details 詳細情報について
-
- CRID
- 1390282679691613440
-
- NII Article ID
- 130006316039
-
- NII Book ID
- AN00191857
-
- ISSN
- 21860211
- 04466454
-
- NDL BIB ID
- 028748721
-
- Text Lang
- ja
-
- Article Type
- journal article
-
- Data Source
-
- JaLC
- IRDB
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed