Effects of Mica and Glass on Surface Hardness of Acrylic Tooth Material

DOI NDLデジタルコレクション NDLデジタルコレクション Web Site Web Site ほか1件をすべて表示 一部だけ表示 被引用文献1件 参考文献30件
  • UNALAN Fatma
    Department of Prosthodontics, Faculty of Dentistry, Istanbul University
  • DIKBAS Idil
    Department of Prosthodontics, Faculty of Dentistry, Yeditepe University

書誌事項

公開日
2007
資源種別
journal article
DOI
  • 10.4012/dmj.26.545
公開者
一般社団法人 日本歯科理工学会

この論文をさがす

説明

The purpose of this study was to evaluate the effects of four different ratios of silanized mica filler and milled glass fiber on the surface hardness of an acrylic denture tooth material. Acrylic resin disks made of polymethyl methacrylate (PMMA) used in fabrication of denture teeth were used as the control group. Eight test groups were prepared by adding a ratio of 5%, 10%, 15%, or 20% by weight of silane-treated mica filler or milled glass fibers to the PMMA resin of denture teeth. Surface hardness test was performed for each group. There were statistically significant differences in surface hardness between the control group and 5%, 10%, and 15% mica- and glass-containing test groups (p<0.05). It was determined that addition of 5%, 10%, and 15% of silane-treated mica filler or silane-treated milled glass fiber to the PMMA resin of denture teeth resulted in significantly improved surface hardness.