- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Source and Prevention of Cracking of Hot-Dip Galvanization Coating for Steel Beam-Column Joints
-
- MORI Masanori
- Takenaka Corp.
-
- NAKAGOMI Tadao
- Shinshu University
-
- SUZUKI Itaru
- Sumitomo Metal Co.
-
- KIM Changsu
- Graduate of Shinshu University
Bibliographic Information
- Other Title
-
- 柱梁接合部における溶融亜鉛めっき割れ発生原因とその防止法
Search this article
Description
In case of using hot-dip galvanized steel beam-column joints, cracking of hot-dip galvanization coating occurs, frequently. Simulations of the phenomenon were carried out for different configurations of steel beam column joints. Also, residual stresses by means of welding were measured to consider their effect on the phenomenon. As results, it has been verified that the residual stresses and configuration of the toe of weld were main factors of the phenomenon. Non-Scallop with circular hole type was found to be effective to prevent cracking of hot-dip galvanized steel beam-column joints.
Journal
-
- QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY
-
QUARTERLY JOURNAL OF THE JAPAN WELDING SOCIETY 27 (1), 41-47, 2009
JAPAN WELDING SOCIETY
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282679701784320
-
- NII Article ID
- 10030148544
-
- NII Book ID
- AN1005067X
-
- COI
- 1:CAS:528:DC%2BD1MXntFWrtrg%3D
-
- ISSN
- 24348252
- 02884771
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed