Description

Hearing results of 130 ears operated on by type III tympanoplasty were reviewed. Postoperative air-bone gap was less than 10dB in 70 ears (53.8%) and less than 20dB in 105 ears (80.8%). There was no statistical difference in hearing results between chronic middle otitis with and without cholesteatoma. There was statistical difference in mean postoperative air-bone gap between the cases used ossicles and the cases used cortical temporal bone chips (Post-hoc test, p<0.05).