書誌事項
- タイトル別名
-
- EXPERIMENTAL DETERMINATION OF MINIMUM DIMENSIONS OF GOING AND RISE NEEDED FOR SAFETY ON STAIRS : Safety requirements of stairs during traverse Part 1
- アンゼンセイ ヨリ ミタ カイダン ノ トウメン ケアゲ ノ サイテイ スンポ
この論文をさがす
説明
Research was conducted to determine minimum required dimensions for rise and going of stairs from the viewpoint of safety during traverse. Five experimental stairs were used to realize maximum range of dimensional varieties that are encountered in Japan. Four young male subjects climbed up and down the stairs : their behaviour on the stairs and impact force they apply to the tread were measured and analysed. Detailed examination of the data suggests that minimum allowable going is 210 mm to assure firm support by the ball joint of the foot, and that maximum allowable rise is 180 mm. This value for rise is too low compared to existing stair dimensions, that other measures to secure safety during stair climbing should be provided.
収録刊行物
-
- 日本建築学会計画系論文報告集
-
日本建築学会計画系論文報告集 356 (0), 24-29, 1985
一般社団法人 日本建築学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679753428864
-
- NII論文ID
- 110004085662
-
- NII書誌ID
- AN10040144
-
- ISSN
- 24330043
- 09108017
- http://id.crossref.org/issn/09108017
-
- NDL書誌ID
- 3050028
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDLサーチ
- Crossref
- CiNii Articles
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可