- MEASUREMENT OF AIR CHANGE EFFECTIVENESS USING METHOD OF INFILTRATION VALUE : Study on ventilation system of house Part 2
- ロウニュウクウキ ノ エイキョウ オ コウリョ シタ カンキ コウリツ シヒョ
この論文をさがす
抄録
This paper described the field measurement results of the local mean age of air which was defined the time of air reaching to the measuring points, and the local air change effectiveness in the wooden detached house. The evaluation of infiltration is indispensable because there are many variation of the infiltration (natural ventilation) in comparison with the office building. However, it is difficult to evaluate the amount of infiltration quantitatively as for the infiltration because it changes by the difference in temperature outside the inside and the wind speed and direction. When ventilation is evaluated by the measurement of local mean age of air, they must evaluate local mean age of air of the amount and change of infiltration. The air change effectiveness changed in the amount of infiltration and age of air of the infiltration were put in the consideration was examined which was by this paper. As a result, how to calculate the amount of infiltration of every measurement point by using response factor method with the outside wind speed and a difference in indoor and outside temperature was tried, and have a good result which get age of infiltration air.
収録刊行物
-
- 日本建築学会計画系論文集
-
日本建築学会計画系論文集 63 (512), 33-37, 1998
日本建築学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282679758302720
-
- NII論文ID
- 110004655221
-
- NII書誌ID
- AN10438548
-
- ISSN
- 18818161
- 13404210
-
- NDL書誌ID
- 4585786
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可