EXPERIMENTAL STUDY ON TEMPERATURE VARIATIONS IN THE ATTIC SPACE OF CEILING INSULATION MODEL AND IN THE VENTILATED AIR SPACE OF ROOF INSULATION MODEL IN INCLINED ROOF DURING WINTER : Ventilation method in attic space of insulated and airtight house to prevent snowmelting in cold region Part 1

Bibliographic Information

Other Title
  • 傾斜屋根における天井断熱・屋根断熱モデルの冬期温度特性について : 積雪寒冷地の断熱気密化住宅における小屋裏換気手法に関する研究(その1)
  • ケイシャ ヤネ ニ オケル テンジョウ ダンネツ ヤネ ダンネツ モデル ノ

Search this article

Abstract

Temperature variations of full-size ceiling insulation model and roof insuration model are measured and observed to prevent melting and freezing of snow on the roof during winter. As a result, roof insulation model with ventilated air space is quite effective to prevent the problem caused by snowmelting on the roof since the temperature inside the ventilated air space follow the outside temperature well. On the other hand, ceiling insulation model leaves much room for improvement on ventilaion method in attic space because of the bad followrity of temperature inside the attic space.