Properties of Addition-Type Silicone Impression Materials
-
- HAMAOKA Masanori
- The First Department of Prosthodontics, School of Dentistry, Showa University
-
- SUGINO Shinya
- The First Department of Prosthodontics, School of Dentistry, Showa University
-
- ISHIDA Kazuhiro
- The First Department of Prosthodontics, School of Dentistry, Showa University
-
- WARITA Kenji
- The First Department of Prosthodontics, School of Dentistry, Showa University
-
- KAWAWA Tadaharu
- The First Department of Prosthodontics, School of Dentistry, Showa University
Bibliographic Information
- Other Title
-
- 付加型シリコーン印象材の理工学的性質について
Search this article
Description
現在, 国内で市販されている付加型シリコーン印象材, 5製品14種類の理工学的性質を, ADA規格No.19を用いて比較検討した。その結果, 今回検討した付加型シリコーン印象材は, いずれも従来の縮合型シリコーン印象材と比較して, 永久歪および経時的寸法変化は小さく, 細部再現性および石膏適合性も同程度であり, 優れた理工学的性質を有していることが確認された.しかしながら, 圧縮歪が小さいため印象材として硬い性質があると考えられる.また, 本実験に使用した国産3製品のパテ・タイプに限れば, 付加型シリコーン印象材本来の優れた理工学的性質を得るためには, メーカーが指示している口腔内撤去時間よりも, 約2-4分長く口腔内に保持する必要があると思われる。