無抗凝固剤透析の検討  流体力学的面から検討を加えた無抗凝固剤専用回路の試作

書誌事項

タイトル別名
  • Study of non-anticoagulant hemodialysis.
  • ―流体力学的面から検討を加えた無抗凝固剤透析専用回路の試作―

この論文をさがす

説明

At present, a number of reports says hemodialysis without anticoagulant is appropriate as a treatment to hemorrhagic complications in hemodialyzed patients, the use of EVAL membrane which is composed of high molecule is particularly effective as a method. We aimed at the process of coagulation in the blood circuit (especialy, in the drip chamber) of extracorporal circuit and examined it at the aspect of hydrodynamics. By improving the chamber with equalized watercourse in each chamber and decreased blood stagnation, easy and stabilized hemodialysis without anticoagulant could be performed with various dialyzers without limiting membrane material and so on when it was used 80 times clinically. Furthermore, though the changes in blood properties affected the usage of hemodialysis without anticoagulant, the time blood coagulated during it could be grasped and it was performed smoothly by using thromboelastgram. From the above mentioned, it becomes clear that maintaining blood quantity equally in the circuit inhibits an effect of membrane material or structure of port's part.

収録刊行物

  • 人工臓器

    人工臓器 14 (1), 66-71, 1985

    一般社団法人 日本人工臓器学会

詳細情報 詳細情報について

  • CRID
    1390282679933275136
  • NII論文ID
    130001736264
  • DOI
    10.11392/jsao1972.14.66
  • ISSN
    18836097
    03000818
  • 本文言語コード
    ja
  • データソース種別
    • JaLC
    • CiNii Articles
  • 抄録ライセンスフラグ
    使用不可

問題の指摘

ページトップへ