The Study on Hepatic Blood Flow Determination by Au<sup>198</sup> Colloid Using Deviced Recording Method
-
- IIO Masahiro
- Second Department of Internal Medicine, Faculty of Medicine, University of Tokyo
-
- KAMEDA Haruo
- Second Department of Internal Medicine, Faculty of Medicine, University of Tokyo
-
- UEDA Hideo
- Second Department of Internal Medicine, Faculty of Medicine, University of Tokyo
Search this article
Description
(1) A simple new recording apparatus for R.I. was deviced and its usefulness was discussed.<br>(2) Using this apparatus, hepatic blood flow was determined in 152 cases by Au198 colloid method.<br>(3) Simultaneous determinations of Au198 disappearance rate constant at periphery (Kp and KH) and accumulation rate constant in the liver (KL) were made in various diseases, such as liver cirrhosis and congestive heart failure etc.<br>(4) Similar examination is also made after rapid blood transfusion or administration of various drugs, including epinephrine, norepinephrine etc.<br>(5) The K value decreased in congestive heart failure and liver cirrhosis. An increase in the K value was observed in accordance with an increased cardiac output.<br>(6) An advantage of this method and its clinical significance were dis-cussed.
Journal
-
- Japanese Heart Journal
-
Japanese Heart Journal 1 (1), 17-36, 1960
International Heart Journal Association
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680016154880
-
- NII Article ID
- 130000770922
-
- DOI
- 10.1536/ihj.1.17
-
- ISSN
- 1348673X
- 00214868
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed