同期變流機の整流帯に於ける過渡起磁力に就いて
-
- 大隅 菊次郎
- Elect. Eng. Depart. Waseda University
書誌事項
- タイトル別名
-
- On the Transient M. M. F. in the Commutating-Zone
抄録
The present paper describes a method to obtain the time and space distribu tion of transient magnetomotive force in the commutating zone of synchronous converters, when a sudden change of load occurs. The transient values of direct and alternating current components in the armature are calculated, taking all of the following factors into account; the synchronous and asynchronous torques, the inertias of rotating parts, the inductance of d. c. circuit, the effect of speed on the output of the machine etc. The direct and alternating current magnetomotive forces are then calculated separately, by the formula developed by Professor T. Yamamoto, and the resultant of these two is taken as the actual M. M. F. on the surface of the armature. As a numerical example, this method is applied to the calculation of the transient M. M. F. of a 1000 K. W., 600 volt, 6 phase shunt wound converter, under the sudden change of 500% load.
収録刊行物
-
- 電氣學會雜誌
-
電氣學會雜誌 46 (452), 283-298, 1926
一般社団法人 電気学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680118660992
-
- NII論文ID
- 130003613123
-
- ISSN
- 21876797
- 00202878
-
- データソース種別
-
- JaLC
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可