Study on Surging of Blower : 4th Report, Study on the Surge-Preventing Apparatus
Bibliographic Information
- Other Title
-
- 送風機のサージングの研究 : 第4報, 送風機のサージング防止装置について
- ソウフウキ ノ サージング ノ ケンキュウ 4
Search this article
Abstract
We have shown a method for non-surging of blowers by"the two-valve operation"on the delivery or the suction pipe line. In this paper we show the theoretical and experimental studies on the surge-preventing apparatus with automatic control. As a result, it has been clarified that this method is more useful and effective on the following matters than the others published before : (1) This apparatus and operation are simple, (2) this method can be controlled in high stability, and (3) the loss of energy for eliminating surging is relatively small.