Combined Cycle MHD Power Generation

Bibliographic Information

Other Title
  • 組合せ熱サイクル形MHD発電
  • クミアワセ ネツ サイクルケイ MHD ハツデン

Search this article

Abstract

In open cycle MHD generators operated by combustion gas, only thermal ionization in equilibrium is employed to make the gas conductive, where initial temperature of working gas must be over 3000°C and the efficiency, when combined with steam turbine generators, is expected to be approximately 55%. On the other hand, in closed cycle systems operated by monoatomic gas, it is possible to use nonequilibrium conduction by elevating only electron temperature and to reduce the initial temperature of gas, alleviating the difficulties of high temperature materials. On these considerations, discussions were made on the overall thermal efficiency of a relatively low temperature MHD generator combined with a given steam power plant in connection with the effects of operating parameters of MHD generator, and it was concluded that at the initial temperature of about 2000°C it is possible to get almost the same efficiency with that obtainable at a higher temperature.

Journal

Details 詳細情報について

Report a problem

Back to top