STRUCTURAL PROPERTIES OF STRUCTURAL SEALANT ABOUT 4 SIDED SSG SYSTEMS THAT WAS APPLIED TO GLASS FACADE FOR OVER 20 YEARS
-
- ISHII Hisashi
- LIXIL Corporation, Research Institute
-
- MORI Hideyuki
- Construction S&T., Dow Corning Toray Co., Ltd.
Bibliographic Information
- Other Title
-
- ガラスファサードに20年以上適用された4辺SSG構法の構造シーラントに関する構造特性
- ガラスファサード ニ 20ネン イジョウ テキヨウ サレタ 4ヘン SSGコウホウ ノ コウゾウ シーラント ニ カンスル コウゾウ トクセイ
Search this article
Abstract
This paper indicates adhesive durability of 4 sided structural sealant which was applied to the glass facade for 20 years. Tensile tests about the structural sealant of actual facade were carried out. Results of tensile test were compared with initial data of 20 years ago. The purpose of this study is to ensure the maximum tensile strength and structural properties. Specimen was cut off from the glass unit near the top of the building facade susceptible to wind loads. As a result, most of the specimens reached maximum tensile strength at strain of 50%.<br>All specimens indicated a cohesive failure, also indicated a similar tensile strength compared with the initial value 20 years ago.<br>However, the elongation at maximum tensile strength indicated lower than initial data. Also stiffness was 2 times higher compared to the initial values.
Journal
-
- AIJ Journal of Technology and Design
-
AIJ Journal of Technology and Design 19 (42), 393-396, 2013
Architectural Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680146429440
-
- NII Article ID
- 130004932798
-
- NII Book ID
- AN10531441
-
- ISSN
- 18818188
- 13419463
-
- NDL BIB ID
- 024686913
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed