EXPERIMENTAL STUDY ON BASIC PERFORMANCE OF DEVICES WITH ELECTROMAGNETIC INDUCTION METHOD FOR THE MEASUREMENT OF COVER DEPTH OF REBAR

Bibliographic Information

Other Title
  • 電磁誘導法による鉄筋のかぶり厚さ測定装置の基本性能に関する実験的検討
  • デンジ ユウドウホウ ニ ヨル テッキン ノ カブリ アツサ ソクテイ ソウチ ノ キホン セイノウ ニ カンスル ジッケンテキ ケントウ

Search this article

Description

The performance of latest devices with electromagnetic induction method for the measurement of cover depth of rebar was confirmed by some experiments. The result is as follows. 1) The accuracy of latest devices was almost in the range of the standard value of JASS5T-608. 2) Mixture proportion of concrete and the age of specimen did not influence measurement values of latest devices with electromagnetic induction method.