建築物の地震後の継続使用に関する阻害要因の分析と要求性能の検討

書誌事項

タイトル別名
  • ANALYSIS OF THE BARRIER TO POST-SEISMIC CONTINUOUS USABILITY OF BUILDINGS AND PROPOSAL OF THE RELATED PERFORMANCE REQUIREMENT
  • ケンチクブツ ノ ジシン ゴ ノ ケイゾク シヨウ ニ カンスル ソガイ ヨウイン ノ ブンセキ ト ヨウキュウ セイノウ ノ ケントウ

この論文をさがす

抄録

This paper illustrates barriers and performance requirement of the post-seismic continuous usability of buildings such as city hall, school, gymnasium, and multistory residence. First, the authors gathered information related to the barriers to continuous usability of buildings which were damaged by the 2011 off the Pacific coast of Tohoku Earthquake.<br>Then, using a flowchart, each damage situation was analyzed into several OK/NG patterns for the comprehensive barrier classification. Based on the result of the analysis and prescription of the related design codes, the framework of performance requirement to secure post-seismic continuous usability was investigated. The proposed framework includes several performance levels which are associated with damage limit states to be tolerated in foundation, main structures and nonstructural systems.