Abstract
In this report, it is showed a method of simple adiabatic curing and it is described the quality control of strength in high strength concrete structure using simple adiabatic curing method and results example of S value. The simple adiabatic curing method gives a temperature history to be almost similar to a structure to specimen. The specimen strength that were done simple adiabatic curing shows strength almost the same as core strength at each 28-91 days age. The quality control of strength in high strength concrete structure was carried out adequately by the simple adiabatic curing method.