PERFORMANCE TEST RESULTS OF WATERPROOFING MEMBRENES
-
- TANAKA Kyoji
- Tokyo Institute of Technology
-
- SHIMIZU Ichiro
- Japan Testing Center for Construction Materials
-
- KOIKE Michio
- Chiba Institute of Technology
Bibliographic Information
- Other Title
-
- メンブレン防水層の性能評価試験結果
- メンブレン ボウスイソウ ノ セイノウ ヒョウカ シケン ケッカ
Search this article
Description
Test methods for characterizing and evaluating waterproofing membranes were first described. They are a water-tightness test and eight performance tests such as static puncture resistance, dynamic puncture resistance, resistance to cyclic fatigue, stability of joints between roofing membranes, resistance to sliding on vertical walls, stability at corners in substrate, resistance to high winds and resistance to blistering. Then, we tested four types of roof waterproofing systems, including 4 built-up systems, 10 torch-on systems, 22 sheet-applied systems and 5 liquid-applied systems. It was found out that each systems has different levels in perfomances. On the best of the results, we discussed the character of each waterproofing systems.
Journal
-
- AIJ Journal of Technology and Design
-
AIJ Journal of Technology and Design 1 (1), 6-10, 1995
Architectural Institute of Japan
- Tweet
Keywords
Details 詳細情報について
-
- CRID
- 1390282680150376192
-
- NII Article ID
- 110003800731
- 10005119901
-
- NII Book ID
- AN10531441
-
- DOI
- 10.3130/aijt.1.6
-
- ISSN
- 18818188
- 13419463
-
- NDL BIB ID
- 3975989
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- Crossref
- CiNii Articles
- OpenAIRE
-
- Abstract License Flag
- Disallowed