書誌事項
- タイトル別名
-
- EXPERIMENTAL STUDY ON RESTORING FORCE CHARACTERISTICS EVALUATION OF COLUMN-BEAM (SASHIGAMOI) JOINT
- セイテキカリョク ジッケン ニ モトズク ハシラ-サ カモイ セツゴウブ ノ フクゲンリョク トクセイ ヒョウカ
この論文をさがす
説明
The restoring force characteristics and destruction properties of the different type of column-beam joint were grasped by the experiment. Since the cotter pin joint is hard to produce damage on a column, it is safer than the tusk tenon joint. Restoring force characteristics change a lot with the form and the kind of a pin. There is no difference in the restoring force characteristics by tenon length.<br>When the restoring force characteristics were evaluated based on past research, the experimental results were evaluated in general.