Fe基合金のグロー放電質量分析法における試料形状のイオン電流への影響

  • 岡本 典子
    大同特殊鋼(株)技術開発研究所
  • 坂 貴
    大同特殊鋼(株)技術開発研究所
  • 成田 正尚
    大同特殊鋼(株)技術開発研究所(現:(株)大同分析リサーチ)

書誌事項

タイトル別名
  • Influence of Sample Shape on Ion Beam Current in Analysis of Fe-based Alloy by Glow Discharge Mass Spectrometry
  • Feキ ゴウキン ノ グロー ホウデン シツリョウ ブンセキホウ ニ オケル

この論文をさがす

抄録

For the analysis of trace elemental constituents by glow discharge mass spectrometry, ion beam ratios (IBRs), ratios of ion currents of analysed elements to that of matrix element, are observed. In general, IBRs are affected by the shape for pin-shaped samples or the size of mask for disk-shaped samples. These effects were studied systematically for Febased alloys. For disk-shaped samples, IBRs are rather independent of the mask size provided that the diameter is in the range of 10-15mm. For pin-shaped samples, IBRs depend on the sample shape. However, it has been shown that IBRs for arbitrary shapes can be corrected to that of a standard shape using an experimental equation. The equation for correction is a linear combination of r, L and L2 and F, where r and L are diameter and discharge length of pin-shaped samples, respectively, and F is a parameter for the shape of cross section. IBRs depend on r linearly. On the other hand, they are dependent on the second order of L. The fact indicates that there exists a discharge length (Lext) for each element giving the IBR an extremum. LextS are 3-6mm for the most elements. By using sample whose discharge length is close to Lext, it is possible to minimize the effect of discharge length on IBRS. The present correction shows the possibility to reduce the coefficient of variation for samples of arbitrary shapes from 40% to less than 10%.

収録刊行物

  • 鉄と鋼

    鉄と鋼 83 (3), 181-186, 1997

    一般社団法人 日本鉄鋼協会

被引用文献 (2)*注記

もっと見る

参考文献 (13)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ