Flow Rate Measurement in Unsteady Pipe Flow Through a Plate Orifice

この論文をさがす

抄録

The validity of unsteady flow rate measurement with a plate orifice is examined for pulsating pipe flows and constant-acceleration pipe flows. The conventional steady state relationship between the flow rate and pressure loss through the orifice is applied to these kinds of unsteady flows. The flow rate thus measured is compared to that obtained by integrating the instantaneous velocity distribution over the pipe cross-section. The velocity distribution is measured by traversing a hot-wire probe. The two flow rates are in good agreement with each other.

収録刊行物

  • 実験力学

    実験力学 8 (Special_Issue), s1-s5, 2008

    日本実験力学会

参考文献 (14)*注記