Comparison of Analytical Solutions and Measured Values of Accelerating Laminar Pipe Flow

Bibliographic Information

Other Title
  • 円管内層流加速流れの解析解と測定値との比較
  • エンカンナイ ソウリュウ カソク ナガレ ノ カイセキカイ ト ソクテイチ トノ ヒカク

Search this article

Abstract

An accelerating laminar air flow initially at rest is generated in a circular pipe. Analytical solutions for the axial velocity component and wall shear stress of the flow are derived. Information on these quantities is helpful for a better understanding of the transition to turbulence in accelerating laminar pipe flows. A hot-wire anemometer is used for the measurement of these quantities. Both the measured values of the axial velocity component and wall shear stress before transition to turbulence are found to be favorably predicted by the analytical solutions.