Contrast-enhanced MR Imaging of Metastatic Brain Tumor at 3 Tesla: Utility of T1-weighted SPACE Compared with 2D Spin Echo and 3D Gradient Echo Sequence
-
- KOMADA Tomohiro
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- NAGANAWA Shinji
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- OGAWA Hiroshi
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- MATSUSHIMA Masaya
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- KUBOTA Seiji
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- KAWAI Hisashi
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- FUKATSU Hiroshi
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- IKEDA Mitsuru
- Department of Radiological Technology, Nagoya University School of Health Sciences
-
- KAWAMURA Minako
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- SAKURAI Yasuo
- Department of Radiology, Nagoya University Graduate School of Medicine
-
- MARUYAMA Katsuya
- Siemens-Asahi Medical Technologies, Ltd.
この論文をさがす
説明
We evaluated the newly developed whole-brain, isotropic, 3-dimensional turbo spin-echo imaging with variable flip angle echo train (SPACE) for contrast-enhanced T1-weighted imaging in detecting brain metastases at 3 tesla (T). Twenty-two patients with suspected brain metastases underwent postcontrast study with SPACE, magnetization-prepared rapid gradient-echo (MP-RAGE), and 2-dimensional T1-weighted spin echo (2D-SE) imaging at 3T. We quantitatively compared SPACE, MP-RAGE, and 2D-SE images by using signal-to-noise ratios (SNRs) for gray matter (GM) and white matter (WM) and contrast-to-noise ratios (CNRs) for GM-to-WM, lesion-to-GM, and lesion-to-WM. Two blinded radiologists evaluated the detection of brain metastases by segment-by-segment analysis and continuously-distributed test. The CNR between GM and WM was significantly higher on MP-RAGE images than on SPACE images (P<0.01). The CNRs for lesion-to-GM and lesion-to-WM were significantly higher on SPACE images than on MP-RAGE images (P<0.01). There was no significant difference in each sequence in detection of brain metastases by segment-by-segment analysis and the continuously-distributed test. However, in some cases, the lesions were easier to detect in SPACE images than in other sequences, and also the vascular signals, which sometimes mimic lesions in MP-RAGE and 2D-SE images, were suppressed in SPACE images. In detection of brain metastases at 3T magnetic resonance (MR) imaging, SPACE imaging may provide an effective, alternative approach to MP-RAGE imaging for 3D T1-weighted imaging.<br>
収録刊行物
-
- Magnetic Resonance in Medical Sciences
-
Magnetic Resonance in Medical Sciences 7 (1), 13-21, 2008
日本磁気共鳴医学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680171359616
-
- NII論文ID
- 10024151146
-
- NII書誌ID
- AA11648770
-
- ISSN
- 18802206
- 13473182
-
- PubMed
- 18460844
-
- 本文言語コード
- en
-
- 資料種別
- journal article
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
- KAKEN
- OpenAIRE
-
- 抄録ライセンスフラグ
- 使用不可