Measurements of Internal EGR Distribution in an Engine by Laser Induced Fluorescence

Bibliographic Information

Other Title
  • レーザ誘起蛍光(LIF)法によるエンジン筒内内部EGR挙動計測
  • レーザ ユウキ ケイコウ LIF ホウ ニ ヨル エンジントウ ナイナイブ EGR キョドウ ケイソク

Search this article

Description

<p>A novel diagnostic technique named “Tracer Producing LIF technique” which permits 2-dimensional measurements of internal EGR in an engine cylinder has been developed. The feature of this technique is utilizing a fuel additive which does not emit LIF signal but its combustion products radiate strong LIF emission. Internal EGR behaviors can be measured by observing the LIF images excited by a UV-laser sheet. Firstly, the principle of this technique and selection of fuel additives are described. Then, "Tracer Producing LIF technique" was applied to the visualized engine, in which whole pent-roof area can be observed from the engine side direction. Internal EGR behaviors have been measured from suction to exhaust in whole engine cycle. As a result, gas exchange process between burned gas and air, as well as the influence of the valve timing on the above process were clarified. It was also confirmed that inhomogeneous internal EGR distribution still existed at the ignition timing for the first time.</p>