書誌事項
- タイトル別名
-
- HEAT TRANSFER TO AN EAVE DURING FLAME IMPINGEMENT
- ノキシタブ ニ ショウトツ スル カエン ノ ネツ デンタツ トクセイ
この論文をさがす
抄録
A series of model experiment was conducted for evaluating heat transfer to a non-flammable eave during flame impingement. Excess temperature ΔT and incident heat flux to the eave q″ were measured under sixteen experimental runs with varying parameters of eave section geometry, burner geometry, installation position of the burner, and fuel supply rate. In order to correlate the maximum excess temperature ΔTmax , a reference length scale L was deduced from the governing dimensionless parameter Q*. Dimensional analysis of thermal structure of the flow showed that the maximum excess temperature ΔTmax is expected to be proportional to ((x +H)/L)0 in the flaming regime, and ((x +H)/L)-1 in the non-flaming regime. The agreement with the experimental data was reasonable for all the tested eave sections and burner geometries.
収録刊行物
-
- 日本建築学会環境系論文集
-
日本建築学会環境系論文集 80 (710), 305-313, 2015
日本建築学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680177248128
-
- NII論文ID
- 130005069939
- 200000404894
-
- NII書誌ID
- AA11830377
-
- ISSN
- 1881817X
- 13480685
-
- NDL書誌ID
- 026312576
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDL
- Crossref
- CiNii Articles
- KAKEN
-
- 抄録ライセンスフラグ
- 使用不可