IMPROVEMENT OF WINTER THERMAL ENVIRONMENT IN A TRADITIONAL VERNACULAR HOUSE IN A MOUNTAIN AREA OF NEPAL : Investigation by simulation

Bibliographic Information

Other Title
  • ネパール山岳地帯の伝統的住宅における冬の温熱環境改善 : シミュレーションによる検討
  • ネパール サンガク チタイ ノ デントウテキ ジュウタク ニ オケル フユ ノ オンネツ カンキョウ カイゼン シミュレーション ニ ヨル ケントウ

Search this article

Abstract

For the purpose of thermal improvement in winter and saving firewood, an indoor thermal simulation was conducted in a traditional house in a mountain area of Nepal. The results are as follows: 1) The predicted mean indoor air temperature was -0.3 to 1.3K higher than the measured value. The 'Root Mean Square Error' of the measured and predicted indoor air temperature was 1.0 to 1.8K. The results show that the indoor air temperature is well predicted by the 'Base-Model'. 2) When firewood consumption is reduced by 60% in the 'Integrated-Improved-Model', nighttime indoor air temperature was 1.0 to 4.0K higher than the 'Base-Model'. This shows that the closing of openings to make the building airtight, and insulation of the roof are highly effective for thermal improvement and saving firewood.