書誌事項
- タイトル別名
-
- Thermal Conductivity and Strength of Vermiculite Mortar
- ホンポウサン ヒルイシ ニ カンスル ケンキュウ 2
- Studies on Vermiculite from Japan, (II)
- 本邦産蛭石に関する研究 (第2報)
この論文をさがす
説明
The properties of vermiculite mortar made of the vermiculite from Fukushima, Japan, were discussed. The following tests were carried out on the insulating mortar samples cured in damp air: thermal conductivity, bulk density, compressive strength, tensile strength and modulus of rupture. By means of hand mixing, the expanded vermiculite (temperature of firing: 600°C) and commercial portland cement were mixed until the resultant mass had a uniform color; water (mixed with the neutralized solution of vinsol resin) was then added, and the batch was mixed for about 5 min to have a unifom consistency. From the data presented, the following results were obtained: (a) The bulk density of mortar decreased as the vermiculite content increased. (b) The lower-density mortars had lower strength but higher insulation value. (c) The effect of vermiculite content on thermal conductivity was greater in the range of 1:1-4 than in the range of 1:4-9 (cement: vermiculite); the rate of decrease in the conductivity with the increase of vermiculite content changed abruptly at about 1:4 mixture. (d) The effect of vermiculite content on strength was greater in the range of 1:0-1 mixtures than in the range of 1:2-4 mixtures; the curve in the range between 1:0-1 was steeper than in the range between 1:2-4. (e) For general construction purposes except the most unusual load conditions, the best mortar can be produced with a 1:4 mixture in accordance with Scholes and his coworkers' results for N. Carolina vermiculite. The properties of this mixture (by use of 475 litres of H2O per cu. m. of vemiculite and a mixing time of 5 min) after 28 days were as follows: Thermal conductivity, λt (kcal/m hr °C), at the mean temperature of t (°C): λt=0.0605+0.000191×t; bulk density: 0.902; compressive strength: 18kg/cm2; tensile strength: 7kg/cm2; modulus of rupture: 16kg/cm2 (f) The vermiculite mortars produced with 1:8-9 mixtures had higher insulation values than the loose-filled vermiculite (expanded at firing temperature of 700°C) pressed by 20 per cent. (g) Data on thermal conductivity, bulk density and strength of vermiculite mortars having various ratios of cement: vermiculite were given. (h) Expanded “Fukushima vermiculite” would be excellent as an aggregate for light-weight mortar with high insulation value.
収録刊行物
-
- 窯業協會誌
-
窯業協會誌 64 (724), 135-139, 1956
公益社団法人 日本セラミックス協会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680192336512
-
- NII論文ID
- 110002318321
-
- NII書誌ID
- AN00245650
-
- COI
- 1:CAS:528:DyaG2sXmvVOksA%3D%3D
-
- ISSN
- 18842127
- 00090255
- http://id.crossref.org/issn/00090255
-
- NDL書誌ID
- 10125332
-
- 本文言語コード
- ja
-
- データソース種別
-
- JaLC
- NDLサーチ
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可