- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Fundamental Study on Pepsinogen I and II Levels Using Latex Turbidimetric Immunoassay
-
- Komatsu Tomoya
- Department of Clinical Laboratory, JR East Health Promotion Center
-
- Mizoguchi Toshikazu
- Department of Clinical Laboratory, JR East Health Promotion Center
-
- Inose Mitsuhiro
- Department of Clinical Laboratory, JR East Hospital
Bibliographic Information
- Other Title
-
- ラテックス免疫比濁法を用いたペプシノゲンⅠおよびペプシノゲンⅡの評価
- ラテックス免疫比濁法を用いたペプシノゲン1およびペプシノゲン2の評価
- ラテックス メンエキヒ ダクホウ オ モチイタ ペプシノゲン 1 オヨビ ペプシノゲン 2 ノ ヒョウカ
Search this article
Description
Objective: Pepsinogen I and II (PG I and PG II) levels in the blood are good indicators of gastric activity, and can be used independently or in combination to monitor for peptic ulcer and atrophic gastritis in the screening of patients at high risk of stomach cancer. In particular, PG I/II ratio is being increasingly used in routine health screening and other medical check-ups. In the present study, CIAS LATEX™ PG I and PG II latex immunoassays were evaluated with regard to fundamental performance and screening in medical check-ups.<br>Materials and Methods: Assays were performed using a TBA™-c8000 automated analyzer. A total of 678 samples obtained during medical checkups were analyzed. <br>Results: The fundamental performance of the assay was good. In a clinical assessment, positive rates for the latex immunoassay and chemiluminescent assay were 8.0% and 12.6%, respectively. The coincidence rates were 95.1%, and 96.9% of disagreements were positive for the chemiluminescent assay but negative for the latex immunoassay. In addition, upper esophagogastroduodenoscopy and endoscopic diagnosis findings for 51 subjects in whom there was disagreement for both assays produced concordance rates of 68.6% for the latex immunoassay and 56.9% for the chemiluminescent assay. The positive rate increased with age. It was <3% in the <49 years group and >11% in the >50 years group.<br>Conclusions: The results reported here indicate that the accuracy and precision of the latex immunoassay were very high. Also, as this assay can be adapted for use with a universal automated analyzer, it would be useful in pepsinogen level testing in health screening and other medical check-ups.
Journal
-
- Official Journal of Japan Society of Ningen Dock
-
Official Journal of Japan Society of Ningen Dock 24 (4), 870-878, 2009
Japan Society of Ningen Dock
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680211815168
-
- NII Article ID
- 10026138789
-
- NII Book ID
- AA12055286
-
- ISSN
- 21865027
- 18801021
-
- NDL BIB ID
- 10546983
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- NDL Search
- CiNii Articles
-
- Abstract License Flag
- Disallowed