FATIGUE PERFORMANCE OF CONNECTIONS BETWEEN STRINGERS AND FLOORBEAMS IN STEEL RAILWAY TRUSSES AND ITS IMPROVEMENTS
-
- TAKAHASHI Kazuya
- 東海旅客鉄道株式会社
-
- NAITO Shigeru
- 東海旅客鉄道株式会社
-
- SEKI Masaki
- 東海旅客鉄道株式会社
-
- ICHIKAWA Atsushi
- 財団法人鉄道総合技術研究所
-
- MIKI Chitoshi
- 東京工業大学 理工学研究科土木工学専攻
Bibliographic Information
- Other Title
-
- 鋼鉄道トラス橋縦桁横桁連結部の疲労特性とその改善方法
Description
Much fatigue damage has been observed in connections between stringers and floorbeams in initially-welded steel railway bridges. In this study, static loading tests and fatigue tests on full-scale connections between stringers and floorbeams were carried out in order to identify fatigue performance, with the objective of improving fatigue performance so that life extension methods for the connections could be developed. As a result, it became clear that the existing connections were susceptible to fatigue damage in predictable locations, and that this low fatigue performance resulted in increased stress in the surrounding area. It was also found that a certain reinforcement method was effective in reducing stress in the fatigue damaged areas.