CENTRIFUGAL MODEL TESTS ON LATERAL BEARING CAPACITY OF EXISTING CAISSON FOUNDATION REINFORCED BY STEEL PIPE SHEET PILES
-
- ISOBE Koichi
- 京都大学 工学研究科 都市社会工学専攻
-
- KIMURA Makoto
- 京都大学大学院 工学研究科 都市社会工学専攻
-
- YOSHIZAWA Yukihito
- 鋼管杭協会
-
- KOHNO Kenji
- 鋼管杭協会
-
- HARATA Noriyoshi
- 鋼管杭協会
-
- MAKINO Takeshi
- 鋼管杭協会
Bibliographic Information
- Other Title
-
- 鋼管矢板基礎増設による既設橋ケーソン基礎の補強効果に関する実験的研究
Search this article
Description
Steel pipe sheet pile reinforcement method for existing caisson foundation in water, which is driving SPSP around caisson foundation and connecting between SPSP and caisson at the top, is proposed. This method is constructed in practical, but effect of reinforcement and SPSP load ratios, which refers to the total load transmitted from caisson to SPSP reinforcement divided by the total load applied on the SPSP reinforced caisson, is not understood. It is thought that these factors are influenced by caisson-SPSP connection condition and flexural rigidity ratios of caisson to the SPSP and bearing layer's condition. To make these influence clear and recommend easy, cheap and effective construction method, centrifugal tests on these factor are conducted.