- MORETTI Fabio
- University of Pisa-DIMNP
-
- MELIDEO Daniele
- University of Pisa-DIMNP
-
- D'AURIA Francesco
- University of Pisa-DIMNP
-
- HÖHNE Thomas
- Forschungszentrum Dresden-Rossendorf
-
- KLIEM Sören
- Forschungszentrum Dresden-Rossendorf
説明
The present paper documents the CFD code validation activity carried out at the University of Pisa. In particular, the ANSYS CFX-10.0 code was used to simulate one of the experiments conducted at the ROCOM mixing test facility (FZD, Germany), that reproduced the injection of a de-borated slug in one cold leg of a pressurized water reactor (simulated by a salt tracer) with all circulation pumps at steady-state operation. The calculations were run on several grids obtained through different meshing strategies and having different sizes. The numerical results, in terms of normalized concentration of the transported passive scalar in the downcomer and at the core inlet, were compared against corresponding values obtained through experimental measurements of electrical conductivity in the ROCOM facility. Such comparison resulted in a general good qualitative agreement between simulations and experiments, while some discrepancies were evidenced from a quantitative point of view.
収録刊行物
-
- Journal of Power and Energy Systems
-
Journal of Power and Energy Systems 2 (2), 720-733, 2008
一般社団法人 日本機械学会
- Tweet
詳細情報 詳細情報について
-
- CRID
- 1390282680247861376
-
- NII論文ID
- 130000072934
-
- ISSN
- 18813062
-
- 本文言語コード
- en
-
- データソース種別
-
- JaLC
- Crossref
- CiNii Articles
-
- 抄録ライセンスフラグ
- 使用不可