Improvement of Method to Evaluate Particle Size and Penetrability of Ultrafine Cement Grout
-
- HANADA Tatsuo
- Research and Development Laboratory, Taiheiyo Materials Corporation
-
- OKUBO Seisuke
- Department of Systems Innovation, The University of Tokyo
-
- FUKUI Katsunori
- Department of Systems Innovation, The University of Tokyo
-
- HASEGAWA Makoto
- Civil Engineering Technology Division, Shimizu Corporation
Bibliographic Information
- Other Title
-
- 超微粒子セメントを用いたグラウト材の粒子径と注入性評価方法の改良
- チョウ ビリュウシ セメント オ モチイタ グラウトザイ ノ リュウシケイ ト チュウニュウセイ ヒョウカ ホウホウ ノ カイリョウ
Search this article
Abstract
This paper describes study on evaluation method of particle size and penetrability of ultrafine cement grout. Proposed method to evaluate particle size (digital image method) provided larger particle size than the result obtained by the conventional granulometry. The results by digital image method well coincided with penetrability of grout into cracks indicating that the proposed digital image method was right measure to evaluate the particle size of ultra fine cement grout. The proposed method was applied to evaluate the difference between single and double mixings of grout. The result clearly indicated the difference and it can be said that the double mixing was superior for ultrafine cement grout.
Journal
-
- Journal of MMIJ
-
Journal of MMIJ 127 (8), 504-511, 2011
The Mining and Materials Processing Institute of Japan
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680257504000
-
- NII Article ID
- 10029260165
-
- NII Book ID
- AA12188381
-
- COI
- 1:CAS:528:DC%2BC3MXhtlWqs7vK
-
- ISSN
- 18840450
- 18816118
-
- NDL BIB ID
- 11199319
-
- Text Lang
- en
-
- Data Source
-
- JaLC
- NDL
- Crossref
- CiNii Articles
-
- Abstract License Flag
- Disallowed