Availability of Semi-automatic Measurements of Left Ventricular Volume and Ejection Fraction by 2D and 3D Echocardiography
-
- Yoshizumi Kiyoko
- Gunma Prefectural Cardiovascular Center
-
- Toide Hiroyuki
- Gunma Prefectural Cardiovascular Center
-
- Okaniwa Hiroki
- Gunma Prefectural Cardiovascular Center
-
- 岩﨑 美穂香
- 群馬県立心臓血管センター技術部
-
- Kobayashi Yasuyuki
- Gunma Prefectural Cardiovascular Center
-
- 山下 英治
- 群馬県立心臓血管センター循環器内科
Bibliographic Information
- Other Title
-
- 2次元および3次元心エコーにおける左室容量・駆出率自動計測機能の有用性
Search this article
Description
Background: Recently tracking-based echocardiographic ejection fraction (EF) assessment (AutoEF) has been introduced. In addition, recent advances make it possible to quantify the left ventricular (LV) volume in its three-dimensional perspective (3DEF). This study was designed to evaluate the accuracy and reproducibility of these novel semi-automatic measurements using the traditional biplane Modified Simpson method (Simpson) as a reference.<br>Methods: 46 patients (63±12 years old, 37 men, 29 patients represented a LV regional functional abnormalities) in sinus rhythm underwent 2D and 3D echocardiography on Vivid E9 (GE Healthcare, Horten, Norway). LV end-diastolic volume, end-systolic volume, and EF were measured by the four methods: bp-MOD, AutoEF, AutoEF corrected by a user interaction (Interacted AutoEF) and 3DEF. Inter- and intra-observer variability for each method was investigated. Added to this, the accuracy of AutoEF, Interacted AutoEF and 3DEF were compared with that of bp-MOD. Time for each measurement was also documented.<br>Results: AutoEF demonstrated a higher throughput with good reproducibility. However, it tended to assess LV volume smaller than reference, especially on the patients with wall motion abnormalities and/or possible dilated cardiomyopathy. Agreement between Interacted AutoEF and bp-MOD was much better than the Auto EF with the addition of still time saving compared to bp-MOD. 3DEF was also a rapid and robust method, but was not so accurate compared with bp-MOD. Furthermore, the feasibility of 3DEF is limited because of the necessity to use another dedicated probe for 3D echocardiography.<br>Conclusions: AutoEF with manual interaction is a very robust and helpful method to assess EF in routine clinical practice. 3DEF is also a valuable tool, however, there is still room for improvement such as smaller probe and easier operation.
Journal
-
- Japanese Journal of Medical Ultrasound Technology
-
Japanese Journal of Medical Ultrasound Technology 37 (3), 181-190, 2012