- 【Updated on May 12, 2025】 Integration of CiNii Dissertations and CiNii Books into CiNii Research
- Trial version of CiNii Research Knowledge Graph Search feature is available on CiNii Labs
- 【Updated on June 30, 2025】Suspension and deletion of data provided by Nikkei BP
- Regarding the recording of “Research Data” and “Evidence Data”
Ultrasonographic Characterization of Hepatic Malignant Lymphoma for Effective Diagnosis
-
- Okuda Yasunori
- Department of Clinical Laboratory, Ehime Prefectural Central Hospital
-
- Osugi Masumi
- Department of Clinical Laboratory, Ehime Prefectural Central Hospital
-
- Otuka Yasuhiro
- Department of Clinical Laboratory, Ehime Prefectural Central Hospital
-
- Takaishi Osamu
- Department of Clinical Laboratory, Ehime Prefectural Central Hospital
-
- Mori Izumi
- Department of Clinical Laboratory, Ehime Prefectural Central Hospital
-
- Nawa Yuichiro
- Department of Hematology, Ehime Prefectural Central Hospital
-
- Maeda Toshiharu
- Department of Pathology, Ehime Prefectural Central Hospital
Bibliographic Information
- Other Title
-
- 悪性リンパ腫肝浸潤の超音波所見の検討
Search this article
Description
<p>Purpose: This study was conducted to examine whether there are characteristic findings of hepatic malignant lymphoma on B-mode and Doppler ultrasonography.</p><p>Subjects and Methods: Eleven patients (8 men and 3 women, median age 83 years) who were diagnosed with malignant lymphoma by biopsy or hepatectomy after ultrasonography between January 2011 and December 2015 were analyzed retrospectively. Histologically, there were 8 diffuse large B-cell lymphomas, 1 extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue, 1 methotrexate-associated lymphoproliferative disorder and 1 Hodgkin lymphoma.</p><p>Results and Discussion: There was a significant difference in B-mode findings and Doppler findings between tumors with diameters of ≧30 mm and those with diameters of <30 mm (≧30 mm: 6 cases, <30 mm: 5 cases). Tumors with a diameter of ≧30 mm appeared as hypoechoic masses with heterogeneous internal echo, with linear or dotted hyperechoic images. On color Doppler, penetration of normal vessels was observed inside the tumor. Tumors a diameter of <30 mm appeared as hypoechoic masses with homogeneous internal echo, and displayed images that were not suggestive of vascular penetration. Histopathological characteristics did not correlate with ultrasonographic findings in any of the cases.</p><p>Conclusion: We conclude that the ultrasonographic findings of hepatic malignant lymphoma might vary with a diameter of 30 mm. It was suggested that the ultrasonographic differential diagnosis capability of hepatic malignant lymphomas might be improved by assessing the tumor diameter and the internal echo on B-mode and by evaluating the presence or absence of the vascular penetrating image on color Doppler.</p>
Journal
-
- Japanese Journal of Medical Ultrasound Technology
-
Japanese Journal of Medical Ultrasound Technology 43 (1), 22-33, 2018
Japanese Society of Sonographers
- Tweet
Details 詳細情報について
-
- CRID
- 1390282680258748672
-
- NII Article ID
- 130006639023
-
- ISSN
- 18814514
- 18814506
-
- Text Lang
- ja
-
- Data Source
-
- JaLC
- CiNii Articles
-
- Abstract License Flag
- Disallowed