中央径間長400mおよび600m鋼製斜張橋の低塔化が終局強度特性に与える影響

DOI
  • 野上 邦栄
    首都大学東京大学院,都市環境科学研究科都市基盤環境工学専攻
  • 気仙 祐輔
    三井住友建設(株) 東北支店新幹線七戸川作業所
  • 山沢 哲也
    首都大学東京大学院,都市環境科学研究科都市基盤環境工学専攻
  • 森園 康之
    (株)長大東京支社構造事業部
  • 長井 正嗣
    長岡技術科学大学,工学部環境・建設系

書誌事項

タイトル別名
  • Effect of use of short tower on ultimate strength behavior of steel cable-stayed bridges with the center span length of both 400m and 600m

抄録

This paper presents ultimate strength of steel cable-stayed bridges with short tower which are suitable for constructing at the site near an airport in the urban area. The cable-stayed bridges with center span length of both 400-meter and 600-meter whose tower heights were 1/10 and 1/5 of the center span length were designed. Using the designed model, we studied elasto-plastic behavior and ultimate strength of both cable-stayed bridges.<br>From this comparative study, it is presented, even if the height of tower reduced to about half of economical height (1/5 of center span length), that the cable-stayed bridges have ultimate load factor βu of 2.07~2.20 for 400m and 600m-spanned models and are expected to be competitive.