Continuous-flow detoxification treatment of boron-containing wastewater under hydrothermal conditions

  • SASAI Ryo
    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University
  • MATSUMOTO Yukitaka
    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University
  • ITAKURA Takeshi
    EcoTopia Science Institute, Nagoya University

この論文をさがす

抄録

To develop a practical method of treating boron-containing wastewater, we custom designed two laboratory-scale continuous-flow-type hydrothermal mineralization apparatuses. We carried out a hydrothermal treatment using a continuous-flow apparatus, using Ca(OH)2, CaCl2, and both Ca(OH)2 and CaCl2 as mineralizers, under various pH conditions. Our results show that using CaCl2 under optimal pH conditions (pH = approximately 12) allowed for the stable removal of boron from wastewater. One of the precipitates obtained in this process was parasibirskite, which is a natural boron mineral. Finally, because the residual concentration of boron could not be reduced below 10 mg/dm3, we propose a realistic boron removal wastewater treatment system incorporating the hydrothermal mineralization method.

収録刊行物

被引用文献 (1)*注記

もっと見る

参考文献 (12)*注記

もっと見る

詳細情報 詳細情報について

問題の指摘

ページトップへ